???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: http://tede.unaerp.br:8180//handle/tede/61
Full metadata record
DC FieldValueLanguage
dc.creatorMozini, Alexandra Conca Alves-
dc.creator.Latteshttp://lattes.cnpq.br/3824806916698385por
dc.contributor.advisor1Pietro, Rosemeire C. L. R.-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9087280299354837por
dc.contributor.advisor-co1Vansan, Luís Pascoal-
dc.date.accessioned2016-05-20T17:40:07Z-
dc.date.available2009-02-17-
dc.date.issued2006-12-14-
dc.identifier.citationMOZINI, Alexandra Conca Alves. Influence of obturation remnant, after preparation for intra-radicular retention, on the cervical leakage of Enterococcus faecalis. 2006. 95 f. Dissertação (Mestrado em Endodontia) - Universidade de Ribeirão Preto, Ribeirão Preto, 2006.por
dc.identifier.urihttp://tede.unaerp.br:8180//handle/tede/61-
dc.description.resumoO propósito desse estudo foi avaliar, in vitro, a capacidade de selamento do remanescente de obturação com diferentes comprimentos, após confecção do espaço para receber a contenção intra-radicular, frente à infiltração cervical por Enterococcus faecalis. Quarenta e uma raízes de incisivos centrais superiores foram submetidas ao preparo biomecânico com diâmetro cirúrgico correspondente à lima 55 e mesma conicidade nos terços médio e cervical. As raízes foram autoclavadas e as etapas experimentais foram realizadas em fluxo laminar. Os espécimes foram obturados pela técnica da condensação lateral com cimento AH Plus e a remoção do material obturador foi feita imediatamente após a obturação deixando-se 3 diferentes comprimentos do remanescente da obturação radicular: G I. 6 mm (n=11), GII. 4 mm (n=11) e GIII. 2 mm (n=11). Os 8 dentes restantes constituíram os controles positivo e negativo. Os espécimes foram inseridos no interior de eppendorfs com as extremidades cortadas e colocados em contado com o BHI estéril e receberam o inóculo de 1 x 107 UFC/ml a cada 3 dias, com observação diária por 60 dias. Os dados obtidos foram submetidos à Análise de Variância e ao teste de Tukey. Aos 60 dias, o GI. (6 mm) foi semelhante estatisticamente ao GII. (4 mm), ambos com 54,4% dos espécimes com infiltração bacteriana e diferentes (p<0,01) do GIII (2 mm) que, por sua vez, apresentou 100% dos espécimes com infiltração pelo E. faecalis. Concluiu-se que nenhum dos comprimentos de remanescente de obturação foi capaz de impedir a infiltração do E. faecalis.por
dc.description.abstractThe aim of this study was to evaluate in vitro the sealing capacity of radicular obturing material with different lengths, after the canal preparation to receive intraradicular posts and considering the cervical infiltration of Enterococcus faecalis. Forty one roots of superior central incisors were submitted to the biomechanical preparation with the surgical diameter corresponding to the #55 file and similar conicity in medium and cervical thirds. Roots were autoclaved and the experimental steps were performed in a laminar flow chamber. The specimens were obtured with the lateral condensation technique using the AH Plus cement and the removal of the endodontic material were done immediately after the obturation leaving 3 different lengths (n=11) of the remaining radicular obturation: GI. 6 mm, GII. 4 mm and GIII. 2 mm. The 8 remaining teeth were the positive and negative controls. The specimens were inserted into eppendorfs with cut extremity and placed into sterilized BHI broth. The specimens received the inoculum of 1 x 107 UFC/ml to each 3 days, with daily evaluation, during 60 days. Data were submitted to ANOVA and Tukey test. After 60 days of evaluation, it was possible to observe that GI (6 mm) was statistically similar to GII. (4 mm), both presenting 54.4% of specimens with bacterial infiltration and different (p<0.01) from GIII (2 mm), which presented 100% of specimens with E. faecalis contamination. It may be concluded that none of the tested lengths was able to hinder the infiltration of E. faecalis.eng
dc.description.provenanceMade available in DSpace on 2016-05-20T17:40:07Z (GMT). No. of bitstreams: 1 ALEXANDRA CONCA ALVES MOZINI.pdf: 2789997 bytes, checksum: 5ca58e642be270deb3b9062a4fc34366 (MD5) Previous issue date: 2006-12-14eng
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://tede.unaerp.br:8180//retrieve/112/ALEXANDRA%20CONCA%20ALVES%20MOZINI.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade de Ribeirão Pretopor
dc.publisher.departmentEndodontiapor
dc.publisher.countryBRpor
dc.publisher.initialsUNAERPpor
dc.publisher.programPós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectOdontologiapor
dc.subjectEndodontiapor
dc.subjectRetentor Intra-Radicularpor
dc.subjectMicrobiologiapor
dc.subjectDentistryeng
dc.subjectEndodonticseng
dc.subjectIntra-radicular retentioneng
dc.subjectMicrobiologyeng
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleInfluência do remanescente de obturação, após preparo para contenção intra-radicular, na infiltração cervical de Enterococcus faecalispor
dc.title.alternativeInfluence of obturation remnant, after preparation for intra-radicular retention, on the cervical leakage of Enterococcus faecaliseng
dc.typeDissertaçãopor
Appears in Collections:Pos-Graduacao_em_Odontologia

Files in This Item:
File Description SizeFormat 
ALEXANDRA CONCA ALVES MOZINI.pdf2.72 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.