???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: http://tede.unaerp.br:8180//handle/tede/55
???metadata.dc.type???: Dissertação
Title: Influência do aumento do diâmetro cirúrgico sobre a limpeza do terço apical de canais radiculares curvos submetidos ao preparo biomecânico com instrumentos de Níquel-Titânio
Other Titles: Influence of surgical diameter augmentation on cleaning of the apical third of curved root canals submitted to biomechanical preparation with nickel-titanium instruments
???metadata.dc.creator???: Fornari, Volmir João 
???metadata.dc.contributor.advisor1???: Sousa Neto, Manoel D.
???metadata.dc.description.resumo???: Este estudo avaliou, por meio de análise morfométrica, a influência do diâmetro cirúrgico na limpeza dos canais radiculares promovida pelo sistema Hero 642. Quarenta raízes mésio-vestibulares de molares superiores com ângulo de curvatura entre 20° e 40°, raio de curvatura ≤ 10 mm e diâmetro anatômico correspondente ao instrumento 25 foram aleatoriamente divididas em 4 grupos de acordo com o diâmetro cirúrgico do último instrumento: GI 30/.02; GII - 35/.02; GIII 40/.02 e GIV - 45/.02. A irrigação/aspiração entre os instrumentos foi realizada com água destilada. Posteriormente, os terços apicais foram submetidos ao processamento histológico e analisados com aumento de 40X. As imagens foram capturadas pelo software Adobe Premier 5.1 e a analisadas com auxilio de uma grade de integração do software Corel PhotoPaint 12. O perímetro de ação dos instrumentos nas paredes dos canais radiculares foi determinado com auxilio do software Scion Image for Windows. Os dados obtidos foram submetidos à análise de variância e teste de Tukey, considerando-se a presença de debris (PD) no terço apical e a quantidade de dentina sem contato (SC) com o instrumento. A análise estatística não demonstrou haver diferença (p>0,05) entre GIII (PD-15.82% ± 6.66; SC- 38.08% ± 10.44) e GIV (PD -12.78% ± 3.11; SC-32.35% ± 8.51), os quais apresentaram melhores resultados que GI (PD-34.62% ± 9.49; SC-55.64% ± 4.62) e GII (PD -25.33% ± 7.37; SC-49.03% ± 5.70). O teste de correlação de Pearson demonstrou haver uma relação diretamente proporcional entre a quantidade de debris apical e a área do canal sem contato instrumento. Concluiuse que o preparo dos canais com instrumentos Hero 642 de maior diâmetro cirúrgico permitiram maior contato com as paredes do canal, proporcionado uma limpeza mais efetiva no terço apical do canal radicular.
Abstract: This study evaluated the influence of the surgical diameter on the cleaning capacity of Hero 642 system in root canals, using morphometric analysis. Roots of forty maxillary molars with curvature angle between 20° and 40°, curvature ratius ≤ 10 mm and diameter corresponding to the 25 instrumnets were randomly divided into 4 groups according to the surgical diameter of the last instrument: GI 30/.02; GII - 35/.02; GIII 40/.02 and GIV - 45/.02. Distilled water was used for irrigation. The apical thirds were submitted to histological processing and analyzed at 40X magnifying. The images were captured and submitted to morphometric analysis with an integration grid. The action perimeter of the instruments on the root canal walls was determined with Software Scion Image. Data were analyzed by ANOVA and Tukey test considering the debris presence (DP) in root apical third and dentin without instrument contact (IC). The statistical analysis showed no significant difference (p>0.05) between GIII (DP-15.82% ± 6.66; IC-38.08% ± 10.44) and GIV (DP-12.78% ± 3.11; IC-32.35% ± 8.51), which presented better results than GI (DP-34.62% ± 9.49; IC-55.64% ± 4.62) and GII (DP-25.33% ± 7.37; IC-49.03% ± 5.70). Pearson s correlation test displayed a liner relation between the amount of apical debris and the area without instrument contact. It may be concluded that root canal preparation with Hero 642 instruments of higher diameters allowed more contact with the root canal walls and were also more efficient on debris removal.
Keywords: Odontologia
Endodontia
Canal Radicular
Tratamento
Dentistry
Endodontics
Root Canal
Treatment
???metadata.dc.subject.cnpq???: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
Language: por
???metadata.dc.publisher.country???: BR
Publisher: Universidade de Ribeirão Preto
???metadata.dc.publisher.initials???: UNAERP
???metadata.dc.publisher.department???: Endodontia
???metadata.dc.publisher.program???: Pós-Graduação em Odontologia
Citation: FORNARI, Volmir João. Influence of surgical diameter augmentation on cleaning of the apical third of curved root canals submitted to biomechanical preparation with nickel-titanium instruments. 2006. 106 f. Dissertação (Mestrado em Endodontia) - Universidade de Ribeirão Preto, Ribeirão Preto, 2006.
???metadata.dc.rights???: Acesso Aberto
URI: http://tede.unaerp.br:8180//handle/tede/55
Issue Date: 25-Oct-2006
Appears in Collections:Pos-Graduacao_em_Odontologia

Files in This Item:
File Description SizeFormat 
VOLMIR JOAO FORNARI.pdf4.41 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.